Routine Inspection
- Performed by the fire fighter after each use.
- Look for:
-
— Soiling.
— Contamination.
— Physical damage.
— Damaged or missing trim.
— Loss of seam integrity or missing stitches.
— Correct assembly of components.
Advanced Inspection
- Performed annually by fire department’s trained personnel or verified Independent Service Provider (ISP).
- Ensemble elements that are “soiled” must be cleaned before inspection.
- Findings of inspection must be documented.
- Include all elements of routine inspection.
- Perform required tests on garment elements:
-
— Light evaluation test
of liners.
— Leakage evaluation.
Complete Liner Inspection
- Performed annually on garments in use for three years or longer by fire department’s trained personnel or verified ISP.
- Liner must be separated to expose the hidden sides of the moisture barrier and thermal liner.
- Perform required test on
moisture barrier:
-
— Water penetration barrier evaluation.
- Liners that pass inspection must
be sewn
together after testing.